Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T05CM05972

Parcel: 10321671A

Inspection Status: Approved

Inspection History: PLUMBING - ABOVE CEILING

Date Description Inspector Results Comments
03/09/2006 PLUMBING - ABOVE CEILING Approved IVRS - Inspection :*
03/07/2006 PLUMBING - ABOVE CEILING Partial Approval IVRS - Inspection :*
1. ABS IS TO BE SUPPORTED AT EACH CHANGE OF DIRECTION OR ELEVATION, AND AT THE END OF BRANCHES AND THRU NO MORE THAN FOUR FEET BETWEEN SUPPORTS. SUPPORTS TO BE APPROVED TYPE (LISTED)
2. OK TO INSULATE HOT - OK TO COVER WALL
3. N/H BAND NOT APPROVED CONNECTOR FOR ABS