Permit: T05CM05972

Parcel: 10321671A

Inspection Status: Approved

Inspection History: PLUMBING - ABOVE CEILING

Permit Number - T05CM05972

Inspection Description - PLUMBING - ABOVE CEILING

Inspection Status - Approved

Date Description Inspector Results Comments
03/09/2006 PLUMBING - ABOVE CEILING Approved IVRS - Inspection :*
03/07/2006 PLUMBING - ABOVE CEILING Partial Approval IVRS - Inspection :*
1. ABS IS TO BE SUPPORTED AT EACH CHANGE OF DIRECTION OR ELEVATION, AND AT THE END OF BRANCHES AND THRU NO MORE THAN FOUR FEET BETWEEN SUPPORTS. SUPPORTS TO BE APPROVED TYPE (LISTED)
2. OK TO INSULATE HOT - OK TO COVER WALL
3. N/H BAND NOT APPROVED CONNECTOR FOR ABS