Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T05CM05971
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
06/13/2006 | FRAMING | Approved | IVRS - Inspection :* | |
06/12/2006 | FRAMING | Not ready for Inspection | IVRS - Inspection :* 1) NOT READY PER DENNIS |
|
05/17/2006 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NAIL SHEAR AT WATER HEATER PLATFORM 2) ROMEX DAMAGED WEST OF BACK DOOR/CEILING 3) SUPPORT COPPER LINE UNDER STAIRS 4) SUPPORT ABS IN CEILING HALLWAY 5) DBL TOP PLATE ABOVE FRONT DOOR AT EAST CORNER 6) NEED FIRE STOP IN GARAGE WEST WALL 7) MISSING SHEET ON FLOOR AT TOP OF STAIRS 8) BANG PLATES THROUGHOUT 9) BATH 2ND FLOOR WINDOW CALLS FOR 2-2 X 4 UNDER HEADER AND ALL 4' WINDOWS SHIMS DBL TOP PLATE 2ND FLOOR NORTHWEST CORNER 10) STOPPED INSPECTION |