Permit: T05CM05970

Parcel: 141091040


Addresses:

6625 E WRIGLEY WY

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
03/31/2006 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
03/28/2006 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection :*
1) BEING DBL STUDS DOWN FROM 1ST/2ND FLOOR AND BETWEEN FLOORS
03/24/2006 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) FRONT HEADER TOP OF WINDOW TO BE DBL 2 X 10"
2) NEED 1ST/2ND FLOOR STRAPS, 48" ON CENTER 12" ABOVE AND BELOW FLOOR TRUSS USE 150
3) 2/DT2 REQUIRES 16D'S AT 8" ON CENTER
4) 1/DT2 REQUIRES 16D'S AT 4" ON CENTER
5) HUS20 HANGERS AT GIRDER TRUSS REQUIRES MINIMUM 16 SINKER HANGER CARRIES 3,0035 WITH 16D COMMONS TRUSS LOAD 919 POUNDS