Inspection History Details
Inspection Status: Approved
Inspection History: BUILDING - FINAL
Permit Number - T05CM05966
Inspection Description - BUILDING - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
07/12/2006 | BUILDING - FINAL | Approved | IVRS - Inspection :* | |
07/11/2006 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) COACH LIGHT NOT INSTALLED. PROVIDE CITY OF TUCSON APPROVED SUBMITTAL FOR LIGHT 2) INSPECTION OF UNDERGROUND FOR COACH LIGHT MUST BE MADE 3) TRENCH IS TO SHALLOW, UNLESS METAL CONDUIT 4) ONE CIRCUIT IN PANEL NOT LABELED 5) STUCCO WEEP SCREED CANNOT BE COVERED WITH CONCRETE-REQUIRES 2" EXPOSURE 6) DISHWASHER DRY IN MUST LOOP TO WITHIN 2" OF SINK FLOOD RIM |