Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T05CM05956

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
03/08/2006 FRAMING Approved IVRS - Inspection :*
03/02/2006 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) SHALL NOT HAVE VENT SYSTEM MORE THAN 60 DEGREE OFF SET PER G2427.6.4 IRC
03/01/2006 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) REPAIR CONDENSATE AT GARAGE ABS NAIL PLATE 2ND FLOOR
2) FLU PIPE HAS NEGATIVE PITCH AT FLOOR JOIST?
3) FIRE BLOCK MISSING AT STAIR WAY
4) FIRE BLOCK DUCT CHASE 2ND FLOOR
5) PROVIDE 1" CLEARANCE FLU PIPE 2ND FLOOR
6) SHIM A11 HEADERS