Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T05CM05928
Inspection Description - FRAMING
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/16/2008 | FRAMING | Approved | IVRS - Inspection :* | |
| 04/15/2008 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NEED DWV TEST 2) RELOCATE SMOKIE |
|
| 04/08/2008 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NEED PROTECTION PLATES ON TRAP ARM AT KITCHEN SINK 2) PROTECTION PLATES ON WATER SUPPLY LINES, HALL-WAY CEILING 3) NO DWV TEST ON PLUMBING 4) NEED TO FIRE SEAL-FURRED OUT WALL AT CEILING 5) INSULATE WATER SUPPLY LINES TO ENCASED IN CONCRETE AT BEDROOM 6) NEED TO BUILD SOFFIT FOR ELECTRICAL WIRING AT BEDROOM |
|
| 03/20/2007 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) BATH WINDOW MISSING 2) DOOR NOT ON PLAN 3) WINDOW AND DOOR SIZES NOT PER PLAN 4) JOIST HANGERS MISSING NAILS 5) NEED VERIFICATION OF BEAM BOLTED INTO METAL BEAM SEAT 6) PLAN CALLS FOR 5 1/4" X 11 1/4" LVL BEAM 7) PLAN SHOWS 4 X 12 BEAM EXISTING-OTHER TYPE EXISTS 8) 2 SKYLIGHTS NOT FRAMED IN 9) EXISTING 2 X 10 RAFTERS CUT SHORT TO HAVE LONGER NAILS INTO BEAM THROUGH HANGERS 10) MUST MAINTAIN 1/4" PER FOOT ROOF SLOPE 11) HEADER SIZES NOT PER PLAN 12) INCOMPLETE 13) STOPPED INSPECTION |