Permit: T05CM05928

Parcel: 115211240

Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T05CM05928

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
04/16/2008 FRAMING Approved IVRS - Inspection :*
04/15/2008 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NEED DWV TEST
2) RELOCATE SMOKIE
04/08/2008 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NEED PROTECTION PLATES ON TRAP ARM AT KITCHEN SINK
2) PROTECTION PLATES ON WATER SUPPLY LINES, HALL-WAY CEILING
3) NO DWV TEST ON PLUMBING
4) NEED TO FIRE SEAL-FURRED OUT WALL AT CEILING
5) INSULATE WATER SUPPLY LINES TO ENCASED IN CONCRETE AT BEDROOM
6) NEED TO BUILD SOFFIT FOR ELECTRICAL WIRING AT BEDROOM
03/20/2007 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) BATH WINDOW MISSING
2) DOOR NOT ON PLAN
3) WINDOW AND DOOR SIZES NOT PER PLAN
4) JOIST HANGERS MISSING NAILS
5) NEED VERIFICATION OF BEAM BOLTED INTO METAL BEAM SEAT
6) PLAN CALLS FOR 5 1/4" X 11 1/4" LVL BEAM
7) PLAN SHOWS 4 X 12 BEAM EXISTING-OTHER TYPE EXISTS
8) 2 SKYLIGHTS NOT FRAMED IN
9) EXISTING 2 X 10 RAFTERS CUT SHORT TO HAVE LONGER NAILS INTO BEAM THROUGH HANGERS
10) MUST MAINTAIN 1/4" PER FOOT ROOF SLOPE
11) HEADER SIZES NOT PER PLAN
12) INCOMPLETE
13) STOPPED INSPECTION