Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T05CM05893
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
05/10/2006 | FRAMING | Approved | IVRS - Inspection :* 1) ITEM 03050 NOT REQUIRED-ALL ELECTRIC |
|
05/08/2006 | FRAMING | Denied | IVRS - Inspection : Work is not complete enough to inspect.| 950* 1) ANCHOR BOLTS REQUIRED WITHIN 12" OF PLATE SPLICES 2) MPA1 CLIPS NOT INSTALLED PER SHEAR SCHEDULE AND 6/DT1 3) SHEAR WALL 9 NOT NAILED PER SHEAR SCHEDULE 4) H1LT1 PINS NOT INSTALLED PER SHEAR SCHEDULE 5) RED HEAD ANCHOR BOLTS LOOSE 6) STOPPED INSPECTION 7) HOUSE NOT COMPLETE ENOUGH TO INSPECT |
|
05/04/2006 | FRAMING | Not ready for Inspection | IVRS - Inspection :* 1) NOT READY PER PAUL |