Permit: T05CM05890

Parcel: 141091780

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
05/16/2006 FRAMING Approved IVRS - Inspection :*
05/11/2006 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
MOVE STUD TO ALLOW SW2 SHEAR TO RUN 1/2" BOLTS AT 24" O.C REQ'D AT SWS WALLS
05/09/2006 FRAMING Denied IVRS - Inspection :
Work is not complete enough to inspect.| 950*
1) ANCHOR BOLTS LOOSE THROUGHOUT
2) ANCHOR BOLTS MISSING THROUGHOUT
3) HOLDOWN MISSING NAILS
4) FIRE BLOCK REQUIRES 2 LAYERS OF 1/2" OSB
5) FIRE BLOCK MISSING AT CHASES
6) MANY FIRE BLOCKS MISSING AND BROKEN THROUGHOUT
7) BLOCK DUCT BOOTS 3 SIDES
8) STOPPED INSPECTION-TOO MANY ITEMS