Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T05CM05889
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
05/10/2006 | FRAMING | Approved | IVRS - Inspection :* 1) ITEM 03050 NOT REQUIRED-ALL ELECTRIC |
|
05/08/2006 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) HOLDOWN NOT INSTALLED 2) FIRE BLOCKS REQUIRE 2 LAYERS OF 1/2" OSB 3) BLOCK TUB SURROUNDS 4) REMOVE BLOCK FROM ATTIC ACCESS |
|
05/03/2006 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) HOLDOWNS NOT INSTALLED 2) NO DWV TEST 3) BLOCK OUT DUCT BOOTS 4) ANCHOR BOLTS MISSING 5) FIRE STOP REQUIRES 2 LAYERS 1/2" OSB 6) BLOCK TUB SURROUNDS 7) REVERSE PITCH RIGHT MASTER LAV 8) REMOVE BLOCK FROM ATTIC ACCESS 9) FIRE BLOCK LT 5050 |
|
05/01/2006 | FRAMING | Not ready for Inspection | IVRS - Inspection :* LATH NOT COMPLETE |