Permit: T05CM05872

Parcel: 119421190


Addresses:

4830 S VALLECANO DR

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
02/28/2006 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
1) PLAN CALLS FOR 56/16D'S HGUS3.25/12 9155 INTO FACE THIS HANGER-125 PERCENT ROOF D. FIR 9,155 POUNDS
2) PAGE 104-INSTALLED 5 210-2 14 16D INTO K.C. FACE PAGE 3-NORMAL 1875 AND MAX 2350
3) DON'T LOAD ROOF
4) WILL CHECK AT INTER
02/24/2006 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) SHEAR TRANSFER AT ENTRY
2) CONTINOUS SHEAR TO CORNER AT ENTRY
3) CONTINOUS STUDS/POSTS UNDER GIRDERS
4) STRAP GLU LAMS TO WALL
5) RAT RUN UPSTAIRS
6) CLIP LEDGER BLOCKS AT LIVING ROOM
02/21/2006 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) SHEAR NOT NAILED TO TOP PLATE THROUGHOUT HOUSE
2) OVER SPAN NORTH WALL
3) BLOCK OUT SHEAR AT KITCHEN VENT
4) NAIL PROTECT PLUMBING FROM OUTSIDE
5) FLOOR TRUSS AT KITCHEN SPANS MORE THAT 24"
6) STOPPED INSPECTION
02/17/2006 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection :*
02/14/2006 EXT METAL CLIPS/EXT SHEATHING Cancelled CANCELLED PER PAPERWORK TURNED IN BY INSPECTOR C. TREVILLYAN