Permit: T05CM05871

Parcel: 119420840

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
02/28/2006 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
1) DON'T LOAD ROOF, DRY IN ONLY-BROKEN TRUSS (A03) ROOF, NEED TRUSS REPAIR DETAIL
2) NO DETAILS SHOWING DRAG STRUT CONNECTION TO TOP PLATE
3) UNDER SIZED HANGER AT GARAGE GLU LAM REQUIRES HGUS3.25/12
02/24/2006 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) CONTINOUS STUDS/POST UNDER GIRDERS
2) SHEAR TRANSFER OVER ENTRY WALL
3) SHEAR DRAG TRUSSES X3
4) BLOCK AND CLIP LEDGERS
02/21/2006 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) 413 SD NOT COMPLIED WITH
2) NAIL PROTECT ELECTRIC CONDUIT FROM OUTSIDE
3) 332 SD NOT COMPLIED WITH
4) 309 SD NOT COMPLIED WITH
5) STOPPED INSPECTION
02/17/2006 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection :*
02/14/2006 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) CABIN TIE CORNERS AND INTERUPTED TOP PLATES
2) SHEAR DRAG TRUSSES
3) SHEAR TRANSFER AT ENTRY
4) OPTIONAL WALK DECK/PARAPET AT REAR NOT PER PLAN-JOISTS TO SIT ON TOP OF BEAM
5) 439/SD REQUIRES BLOCKS AT TOP AND BOTTOM OF LEDGER WITH H2.5'S TOP AND BOTTOM
6) RIBBON NOT PER 326/SD
7) 328/SD REQUIRES TRUSS WITH BLOCKS AT GARAGE RAKE-VERIFY LEDGER REQUIREMENTS
8) H2.5 REQUIRED AT FLOOR TRUSS TO TOP OF LEDGER PER 309/SD
9) STOPPED INSPECTION