Permit: T05CM05866

Parcel: 140410210

Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Date Description Inspector Results Comments
01/11/2006 PLUMBING - INTERMEDIATE Approved IVRS - Inspection :*
1) 7 PSI TEST ON PVC DRAIN PIPING, CLEANOUTS AND EXPANSION AND JOINT INSTALLED OK
2) TEST ON VTR-OK
3) WATER PIPING-OK
12/28/2005 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
ABS WASTE PIPING IN GROUND WITH TRAP PRIMER
CONNECTION OK
WATER TEST TO 10'
12/23/2005 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
1. SHALL PROVIDE 2 PIPE DIAMETERS BETWEEN VENT ENTRY AND WORK OF TRAP TO AVOID S-TRAP
2. PROVIDE CORRECT CONNECTION FOR TRAP PRIMOR WITH NO LEAKAGE.
12/16/2005 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*17 EVAP COOLERS W/CONTROL WIRING & GFI MAINT.POWER