Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - SEWER HCS CONNECT
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/02/2006 | PLUMBING - SEWER HCS CONNECT | Approved | IVRS - Inspection :* | |
| 04/10/2006 | PLUMBING - SEWER HCS CONNECT | Partial Approval | IVRS - Inspection :* HCS TIE IN AT BUILDING OK SEE PAST NOTES. |
|
| 04/07/2006 | PLUMBING - SEWER HCS CONNECT | Partial Approval | IVRS - Inspection :* AIR TEST FROM MANHOLE THRU 8" AND 6" BUILDING SEWER TO BUILDING. 1. NEED TO VIEW HCS. |
|
| 04/06/2006 | PLUMBING - SEWER HCS CONNECT | Partial Approval | IVRS - Inspection :* FROM 8X6 WYE BRANCH AT INV. 2534.07 TO 11 1/2 DEGREE FITTING DUCTILE IRON THRU CLEANOUT AT INV. 2537.47 THRU TO BUILDING AT 2544.90 6" SEWER BEDDING, SHADING, LAYING PER REDLINE IN TRAILER. 1. NEED AIR TEST & VERIFICATION OF GRADE WITH REVISED APPROVED PLAN AT LATER DATE. COVER AT OWN RISK. |
|
| 04/04/2006 | PLUMBING - SEWER HCS CONNECT | Not ready for Inspection | IVRS - Inspection :* PROVIDE FITTINGS TO MAKE CHANGES OF DIRECTION OR INSTALL PIPING IN WITH MINIMUM DEFLECTION. |
|
| 04/03/2006 | PLUMBING - SEWER HCS CONNECT | Partial Approval | IVRS - Inspection :* 8" SDR 35 FROM EXISTING SEWER, NEW MANHOLE 8" TO INV: 2534.07 6" HEADING SOUTH APP. 20' WITH 8"X6" WYE FOR BRANCH HEADING TO C/O AT INV. 2540.56 BEDDING, SHADING, LAYING OK TRACER WIRE OK 1. WILL NEED TO SEE AIR TEST, VERIFICATION OF GRADE AT LATER DATE. |