Permit: T05CM05846

Parcel: 14024060F


Addresses:

1361 E WIEDING RD

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
03/17/2006 PLUMBING - FINAL Approved IVRS - Inspection :*
03/15/2006 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
ALL CLEANOUT PLUGS HAVE NOT BEEN CORRECTED
SHOWER HEADS LEAK AT HOSE CONNECTION
CALL FOR INSPECTION OF ANY UNAPPROVED INSPECTION.
03/03/2006 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) USE A LISTED CLEANOUT PLUG DESIGNATED TO RECEIVE A SCREW IN ORDER TO HOLD COVER. SEE PREVIOUS NOTES
2) DRIP ON PACKING NUT AT WH SOV. TURN HANDLE AROUND TO ALLOW FULL OPENING OF VALVE
3) REMOVE INSULATION AT FLUE PIPING
4) PAINT VENT TERMINATIONS WITH LATEX PAINT FOR UV PROTECTION
02/23/2006 PLUMBING - FINAL Partial Approval IVRS - Inspection :*
SUPPORT OVERHEAD ABS AT 4'
SUPPORT OVERHEAD COPPER AT 6'
PROVIDE PROPER CLEANOUT PLUGS & SCREWS
TERMINATE T&P
PROVIDE ADAPTER AT GRADE FOR EXTERIOR CLEANOUTS
NO PROBLEM FOR TEMP C OF O W/MR. LONGS APPROVAL