Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/22/2006 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 02/21/2006 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) PROVIDE BRACING AT MID POINT 2) STUDS MISSING BETWEEN BATH WINDOWS 3) NAIL PROTECT PLUMBING FROM OUTSIDE 4) COMPLY WITH 413/SD |
|
| 02/17/2006 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NEED PLAN/PERMIT/PAST INSPECTION SHEET ON SITE TO DO RE-INSPECT |
|
| 02/16/2006 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) DRAG STRUT STRAP-HDR TO TOP PLATE AT BACK PATIO 2) TIE BEAM TO POST-BACK PATIO 3) CABIN TIE WALLS N.E. CORNER 4) FIRE BLOCK CHIMNEY 5) H2.5 AT MEDIA CENTER RAFTERS 6) CABIN TIE FRONT PORCH HDR TO GARAGE 7) #3 SHEAR PANEL MISSING -BACK 8) HD AT BACK PATIO MUST BE NAILED TO FULL LENGTH STUDS 9) STOPPED INSPECTION |