Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T05CM05839
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
04/28/2006 | FRAMING | Approved | IVRS - Inspection :* | |
04/27/2006 | FRAMING | Not ready for Inspection | IVRS - Inspection :* 1) NOT READY PER SUPER 2) OK TO INSULATE 3) ITEMS 1, 2, 3 NOT COMPLIED WITH |
|
04/24/2006 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) STUCCO WEEP SCREED CANNOT BE UNDER CONCRETE AT FRONT PORCH 2) A/C COPPER OUT OF WALL GARAGE AND BEDROOM 4 3) FIRE STOP CHASES-2 LAYERS 1/2" OSB OR ONE LAYER 3/4 4) BLOCK DUCT BOOTS 3 SIDES BR-2 5) ATTIC ACCESS BLOCKED BY LOW VOLTAGE 6) CHECK KITCHEN CAN LIGHT POSITIONS |