Permit: T05CM05837

Parcel: 141091650


Addresses:

7941 S TALACO TR

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
04/27/2006 FRAMING Approved IVRS - Inspection :*
04/24/2006 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) FRONT PORCH LATH WEEP SCREED CANNOT BE BELOW CONCRETE
2) OVER SPAN GARAGE MECHANICAL CEILING
3) NO DWV WATER TEST
4) PLUMBING OUT OF KITCHEN PONY WALL
5) PROVIDE 22 X 30 ATTIC ACCESS AT LID
6) STUD CUT BATHROOM (MASTER) WALL
7) FIRE STOP REQUIRES 2 LAYERS 1/2" OSB
8) BEARING STUD BORED MORE THAN 40 PERCENT-ADD STUD SHOE
04/20/2006 FRAMING Not ready for Inspection IVRS - Inspection :*
1) STUCCO MESH NOT COMPLETE
2) NO WATER IN PLUMBING
3) NO KING STUD UNDER GIRDER IN GARAGE
4) S/W CORNER OF GARAGE HOLE FOR WATER LINE MORE THAN 50 PERCENT OF STUD MISSING