Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T05CM05837
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
04/27/2006 | FRAMING | Approved | IVRS - Inspection :* | |
04/24/2006 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) FRONT PORCH LATH WEEP SCREED CANNOT BE BELOW CONCRETE 2) OVER SPAN GARAGE MECHANICAL CEILING 3) NO DWV WATER TEST 4) PLUMBING OUT OF KITCHEN PONY WALL 5) PROVIDE 22 X 30 ATTIC ACCESS AT LID 6) STUD CUT BATHROOM (MASTER) WALL 7) FIRE STOP REQUIRES 2 LAYERS 1/2" OSB 8) BEARING STUD BORED MORE THAN 40 PERCENT-ADD STUD SHOE |
|