Permit: T05CM05832

Parcel: 140325020


Addresses:

3998 E BIG GAME PL


Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T05CM05832

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
05/22/2006 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
05/17/2006 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NO ROOF ACCESS
2) NEED TO SEE PARTIAL APPROVAL
3) ON EXT. CLIPS OK TO COVER
05/12/2006 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NO CHANGE
2) TRUSS BRACING MISSING AT TRUSSES A03, A03A, A04, A04A, A04D AND SC03
05/08/2006 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) SAME AS BEFORE
04/28/2006 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection :*
1) MARKED ON FLOOR-NEED RETRO H.D. AT REAR SLIDER
2) TRUSS A03A IS A 3 PT BEARING, SHIM AT TOP PLATE
04/24/2006 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NAIL OFF SHEAR SOUTH WALL 4" + 12"
2) RETRO H.D. NEEDED WEST SIDE SGD SOUTH WALL
3) TRUSS SHEAR PANELS OVER GARAGE WALL ARE SHORT
4) NAIL ROOF THRU SHEAR PANELS PER 2 ON DT1
5) WALKED ROOF NAILING OK EXCEPT SHEAR PANELS