Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T05CM05832
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
05/22/2006 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
05/17/2006 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NO ROOF ACCESS 2) NEED TO SEE PARTIAL APPROVAL 3) ON EXT. CLIPS OK TO COVER |
|
05/12/2006 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NO CHANGE 2) TRUSS BRACING MISSING AT TRUSSES A03, A03A, A04, A04A, A04D AND SC03 |
|
05/08/2006 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) SAME AS BEFORE |
|
04/28/2006 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | IVRS - Inspection :* 1) MARKED ON FLOOR-NEED RETRO H.D. AT REAR SLIDER 2) TRUSS A03A IS A 3 PT BEARING, SHIM AT TOP PLATE |
|
04/24/2006 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NAIL OFF SHEAR SOUTH WALL 4" + 12" 2) RETRO H.D. NEEDED WEST SIDE SGD SOUTH WALL 3) TRUSS SHEAR PANELS OVER GARAGE WALL ARE SHORT 4) NAIL ROOF THRU SHEAR PANELS PER 2 ON DT1 5) WALKED ROOF NAILING OK EXCEPT SHEAR PANELS |