Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T05CM05825
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
06/23/2006 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
05/03/2006 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | IVRS - Inspection :* 1) REAR ? HOLDOWN NOT ON STUDS 2) ADD EPOXY RETRO 3) OK TO DRY IN |
|
04/28/2006 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. HOLDDOWN IN BACK OF HOUSE NOT ATTACHED. 2. CLIPS AT BACK OF HOUSE CONNECTING TRUSS TO HOUSE ALL MISSING NAILS. 3. GIRDER TRUSS IN GARAGE MISSING DOUBLE STUD. 4. TO MANY DAMAGED STUDS ON EASTSIDE OF HOUSE AT TOP CONNECTION UNDER CLIPS. 5. BANG PLATES AROUND PLUMBING. 6. BOTTOM PLATE ON SOUTHWEST CORNER TO MUCH DAMAGE STOPPED INSPECTION. |