Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/22/2006 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 05/17/2006 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NO ROOF ACCESS 2) HOLDOWNS NOT NAILED 3) COMPLY ITEM #3 FROM PREVIOUS INSPECTION |
|
| 05/08/2006 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) SAME AS BEFORE |
|
| 04/28/2006 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) WRONG SIZE STRAPS AT EACH SIDE GARAGE HEADER 2) MISSING #3 SHEAR BLOCKS THRU OUT 3) MISSING SHEAR TRANSFER PANELS BETWEEN TRUSSES. MAKE SURE YOU NAIL THEM TO ROOF PER PLAN 4) GARAGE TO HOUSE WALL, TRUSS ABOVE NOT MADE PER PLAN CHECK BEARING |