Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T05CM05816

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
06/28/2006 FRAMING Approved IVRS - Inspection :*
06/27/2006 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) AIR INTAKE MUST BE 10 FT FROM SEWER VENT
06/26/2006 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) INSUFFICIENT CRAWL SPACE
2) BENT NAILS UNACCEPTABLE
3) PEX MUST HAVE 12" CLEARANCE TO CAN LIGHTS
4) STUD SHOES REQUIRED AT OVERBORED STUDS-KITCHEN
5) FHA STRAPS REQUIRED AT OVER BORED PLUMBING VENTS-TOP PLATES
6) FRESH AIR INTAKE WITHIN 10' OF PLUMBING VENT
7) GARAGE SHEAR MUST BE NAILED AT TOP PLATE
8) STOPPED INSPECTION-REFEE WILL APPLY
06/21/2006 FRAMING Denied IVRS - Inspection :
1) HEATER IN ATTIC ACCESS
2) H.D.'S NOT NAILED
3) MISSING BOLTS GARAGE BOTTOM PLATE
4) SHIM STUDS UNDER BACK WINDOW
5) WIRE PINCHED BETWEEN STUD AT BACK WINDOW
6) STUCCO MESH NOT NAILED ON BACK PORCH AT TOP
06/16/2006 FRAMING Not ready for Inspection IVRS - Inspection :*
1) PLUMBING NOT READY-RECALL