Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/27/2006 | FRAMING | Approved | IVRS - Inspection :* | |
| 06/26/2006 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) SEAL VAPOR BARRIER AT CONDENSATE DRAIN 2) FRESH AIR INTAKE WITHIN 10' OF PLUMBING VENT 3) FHA STRAPS AND STUD SHOES REQUIRED AT OVER BORING 4) SMOKIE REQUIRED AT ENTRY 5) SHIM HDR'S WHERE NEEDED |
|
| 06/21/2006 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) WATER LINE/PEX IN HALL BATH DAMAGED WEST WALL 2) KING STUD MASTER BATH WEST OF TUB NEEDS SHIMMED 3) NAIL PROTECT WIRES OVER SLIDER 4) MISSING FIRE BLOCKING EAST SIDE OF SLIDER 5) REMOVE WIRING AND WATER LINES FROM PINCHED AREAS THROUGHOUT CEILING |