Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/12/2007 | FRAMING | Approved | IVRS - Inspection :* | |
| 04/04/2007 | FRAMING | Not ready for Inspection | IVRS - Inspection :* | |
| 03/29/2007 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NO ACCESS TO 2ND FLOOR 2) CLEANOUTS REQUIRE COMBOS FACING EACH OTHER (NOT SANTEES) 3) PRIME AND TAPE ALL DAMAGED COATING (PIPE WRENCHES, ETC...) 4) GAS PRESSURE OK 5) UNABLE TO LOCATE PLUMBING PLAN 6) NUMEROUS VIOLATIONS OF PLUMBING IN USE OF INCORRECT FITTINGS AND OF LOCATION OF FITTINGS 7) RECOMMED USE OF LICENSED PLUMBER |
|
| 01/26/2007 | FRAMING | Not ready for Inspection | IVRS - Inspection :* | |
| 01/19/2007 | FRAMING | Not ready for Inspection | IVRS - Inspection :* 1. ALL WINDOWS NOT INSTALLED 2. FRAMING INSPECTION IS DONE WITH INTERMEDIATE INSPECTIONS. 3. NO ROOF ACCESS TO CHECK ROOF NAILING. 4. WIND BRACING NEEDED PRIOR TO ROOF INSPECTION. |