Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/21/2007 | FRAMING | Approved | IVRS - Inspection :* | |
| 09/18/2007 | FRAMING | Partial Approval | IVRS - Inspection :* 1) UNTIL ALL INTERMEDIATES ARE APPROVED |
|
| 09/17/2007 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) WIRING IN KITCHEN EXT. WALLS MISSING AT RECEPTACLE-MORE THAN 12' WITHOUT A RECEPTACLE, NOT PER CODE 2) NEED TO PUT SPLICED WIRES IN A J-BOX SOUTH LIVING ROOM CEILING AND MAD ACCESSIBLE 3) STRAP MECH DUCT IN NEW BATH CEILING 4) INSULATE ALL WIRING COMING THRU MASONRY WALLS |
|
| 02/26/2007 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) ELECTRIC SWITCHES AND RECEPTACLES NOT PER PLAN 2) SMOKE DETECTORS TO BE INTER CONNECTED 3) BEDROOM CIRCUITS TO BE ON ARC FAULT 4) MAKE UP ALL GROUNDS IN BOXES 5) INCORRECT POST TO BEAM CONNECTIONS SEE DETAIL 6 6) PORCH LEDGER TO BE 3" X 8" 7) BEDROOM LEDGER TO BE 3" X 10" 8) BLOCK 3 SIDES MECH DUCTS CEILING 9) NEED LADDER TO CHECK HEAT PUMP WIRING ON ROOF 10) STOPPED INSPECTION-MUST BUILD PER APPROVED PLAN 11) 3 INSPECTIONS-STILL NOT READY-REINSPECTION FEE DUE |
|
| 01/31/2007 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) INCOMPLETE 2) STOPPED INSPECTION 3) SUBMIT AS BUILTS FOR APPROVAL |
|
| 09/22/2006 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) GROUND METAL BOXES 2) SECURE HOME RUNS 3) MISSING CEILING FAN AND OUTLETS LIVING ROOM CIRCUITS 7B AND 1AB 4) MISSING OUTLET KITCHEN NORTH WALL 16A 5) 3 WAY TO CEILING LIGHT KITCHEN NOT COMPLETE 6) COOLER NOT WIRED 7) SMOKE DETECTORS MISSING 8) CEILING FAN MISSING BEDROOM 9) STOPPED INSPECTION |
|
| 07/03/2006 | FRAMING | Not ready for Inspection | IVRS - Inspection :* 1) MUST COMPLETE ALL FRAMING, ELECTRIC, PLUMBING, MECHANICAL AND GAS. RECALL FOR ALL INTERMEDIATES |
|
| 06/29/2006 | FRAMING | Partial Approval | IVRS - Inspection :* 1) 2 X 4 BLOCKING INSIDE EXISTING WITH THROUGH BOLTS TO HOLD LEDGER VERIFIED |
|
| 05/30/2006 | FRAMING | Not ready for Inspection | IVRS - Inspection :* |