Permit: T05CM05774

Parcel: 11709074B


Addresses:

1023 S MEYER AV

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
09/21/2007 FRAMING Approved IVRS - Inspection :*
09/18/2007 FRAMING Partial Approval IVRS - Inspection :*
1) UNTIL ALL INTERMEDIATES ARE APPROVED
09/17/2007 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) WIRING IN KITCHEN EXT. WALLS MISSING AT RECEPTACLE-MORE THAN 12' WITHOUT A RECEPTACLE, NOT PER CODE
2) NEED TO PUT SPLICED WIRES IN A J-BOX SOUTH LIVING ROOM CEILING AND MAD ACCESSIBLE
3) STRAP MECH DUCT IN NEW BATH CEILING
4) INSULATE ALL WIRING COMING THRU MASONRY WALLS
02/26/2007 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) ELECTRIC SWITCHES AND RECEPTACLES NOT PER PLAN
2) SMOKE DETECTORS TO BE INTER CONNECTED
3) BEDROOM CIRCUITS TO BE ON ARC FAULT
4) MAKE UP ALL GROUNDS IN BOXES
5) INCORRECT POST TO BEAM CONNECTIONS SEE DETAIL 6
6) PORCH LEDGER TO BE 3" X 8"
7) BEDROOM LEDGER TO BE 3" X 10"
8) BLOCK 3 SIDES MECH DUCTS CEILING
9) NEED LADDER TO CHECK HEAT PUMP WIRING ON ROOF
10) STOPPED INSPECTION-MUST BUILD PER APPROVED PLAN
11) 3 INSPECTIONS-STILL NOT READY-REINSPECTION FEE DUE
01/31/2007 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) INCOMPLETE
2) STOPPED INSPECTION
3) SUBMIT AS BUILTS FOR APPROVAL
09/22/2006 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) GROUND METAL BOXES
2) SECURE HOME RUNS
3) MISSING CEILING FAN AND OUTLETS LIVING ROOM CIRCUITS 7B AND 1AB
4) MISSING OUTLET KITCHEN NORTH WALL 16A
5) 3 WAY TO CEILING LIGHT KITCHEN NOT COMPLETE
6) COOLER NOT WIRED
7) SMOKE DETECTORS MISSING
8) CEILING FAN MISSING BEDROOM
9) STOPPED INSPECTION
07/03/2006 FRAMING Not ready for Inspection IVRS - Inspection :*
1) MUST COMPLETE ALL FRAMING, ELECTRIC, PLUMBING, MECHANICAL AND GAS. RECALL FOR ALL INTERMEDIATES
06/29/2006 FRAMING Partial Approval IVRS - Inspection :*
1) 2 X 4 BLOCKING INSIDE EXISTING WITH THROUGH BOLTS TO HOLD LEDGER VERIFIED
05/30/2006 FRAMING Not ready for Inspection IVRS - Inspection :*