Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/09/2006 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 04/27/2006 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) PLAN CALLS FOR 3-2 X 4 POSTS UNDER GLB 2) REMOVE STUDS TO VEFIFY GLU LAM BEAM ATTACHMENT 3) NEED 2 X 6'S TAPERED PER PLAN 4) NEED WOOD PLATE ATTACHED TO BLOCKWALL TO ATTACH 2 X 5'S ONTO 5) MUST HAVE CLOSET LIGHTS ADDED TO PLAN 6) NEED ATTIC ACCESS PANEL IN LAUNDRY PER PLAN 7) BLOCK 3 SIDES MECH DUCTA AT CEILING 8) NEED LADDER TO INSPECT ROOF 9) NEED TO COMPLETE PLUMBING-PLUMBING IN EXISTING BATH, NOT INSPECTED-REMOVE SHEETROCK FOR INSPECTION 10) NEED APPROVED TRUSS DRAWINGS |