Inspection History Details
Inspection Status: Approved
Inspection History: ENGINEERING - FINAL
Permit Number - T05CM05720
Inspection Description - ENGINEERING - FINAL
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/29/2007 | ENGINEERING - FINAL | Approved | ||
| 03/29/2007 | ENGINEERING - FINAL | Approved | ||
| 03/28/2007 | ENGINEERING - FINAL | Cancelled | ||
| 03/27/2007 | ENGINEERING - FINAL | Partial Approval | NEEDS TO HAVE A LETTER THAT CLEARLY CERTIFYS THE PROJECT OR PROVIDE AN AS-BUILT SITE PLAN. | |
| 03/21/2007 | ENGINEERING - FINAL | Cancelled | NOT READY, NEEDS CERTIFICATION LETTER | |
| 03/08/2007 | ENGINEERING - FINAL | Partial Approval | OK FOR EXTENSION OF TEMPORARY C OF O. PROVIDE AN ORIGINAL COPY OF THE CETIFICATION LETTER THAT IS STAMPED AND SEALED BY THE ENGINEER. 1. PROVIDE A LETTER OF CERTIFICATION FROM THE AZ REGISTERED P.E. THAT CERTIFYS THAT THE PROJECT WAS CONSTRUCTEDTO THE C.O.T. APPROVED PLANS AND THAT THE DRAINAGE AND R/D BASIN WILL FUNCTION AS DESIGNED. NOTE: THE ENGINEER MUST ADDRESS THE 16 CFS OFFSITE FLOW FROM THE MAVERICK ONTO THIS SITE. THE 6" CORB BLOCKS THIS FLOW. 2. CLEAN UP AND REMOVE ALL CONSTRUCTION MATERIAL AND DEBRIS. JORDAN 481-4509 |
|
| 03/06/2007 | ENGINEERING - FINAL | Partial Approval | OK FOR EXTENSION OF TEMPORARY C OF O. 1. PROVIDE A LETTER OF CERTIFICATION FROM THE AZ REGISTERED P.E. THAT CERTIFYS THAT THE PROJECT WAS CONSTRUCTEDTO THE C.O.T. APPROVED PLANS AND THAT THE DRAINAGE AND R/D BASIN WILL FUNCTION AS DESIGNED. NOTE: THE ENGINEER MUST ADDRESS THE 16 CFS OFFSITE FLOW FROM THE MAVERICK ONTO THIS SITE. THE 6" CORB BLOCKS THIS FLOW. 2. CLEAN UP AND REMOVE ALL CONSTRUCTION MATERIAL AND DEBRIS. |
|
| 02/22/2007 | ENGINEERING - FINAL | Partial Approval | OK FOR EXTENSION OF TEMPORARY C OF O. 1. PROVIDE A LETTER OF CERTIFICATION FROM THE AZ REGISTERED P.E. THAT CERTIFYS THAT THE PROJECT WAS CONSTRUCTEDTO THE C.O.T. APPROVED PLANS AND THAT THE DRAINAGE AND R/D BASIN WILL FUNCTION AS DESIGNED. NOTE: THE ENGINEER MUST ADDRESS THE 16 CFS OFFSITE FLOW FROM THE MAVERICK ONTO THIS SITE. THE 6" CORB BLOCKS THIS FLOW. 2. CORRECT DRAINAGE AT THE NORTHWEST CORNER OF THE NEW BUILDING. 3. COMPLETET ALL PAVEMENT STRIPING. 4. PROVIDE ALL WHEEL STOPS. 5. PROVIDE ALL HANDICAP PARKING STRIPING, DECALS AND SIGNS. 6. CLEAN UP AND REMOVE ALL CONSTRUCTION MATERIAL AND DEBRIS. |
|
| 01/02/2007 | ENGINEERING - FINAL | Partial Approval | OK FOR TEMPORARY C OF O. 1. COMPLETE PAVEMENT STRIPING AND SIGNAGE. 2.CLEAN UP AND REMOVE ALL CONSTRUCTION MATERIAL AND DEBRIS. 3 PROVIDE TRUNCATED DOMES AND H/C PARKING SIGNS. 4. PROVIDE AN ENGINEER'S LETTER OF CERTIFICATION THAT THE PROJECT WAS BUILT IN CONFORANCE WITH THE APPROVED PLANS. |
|
| 12/14/2006 | ENGINEERING - FINAL | Not ready for Inspection | COMPLETE ALL SITE WORK |