Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T05CM05714

Parcel: 11105076B

Inspection Status: Approved

Inspection History: PLUMBING - GAS PRESSURE TEST

Permit Number - T05CM05714

Inspection Description - PLUMBING - GAS PRESSURE TEST

Inspection Status - Approved

Date Description Inspector Results Comments
11/06/2006 PLUMBING - GAS PRESSURE TEST Approved IVRS - Inspection :*
10/25/2006 PLUMBING - GAS PRESSURE TEST Denied IVRS - Inspection :
See detailed listing on site.| 999*
PIPING NOT PER PLAN.
HAVE PLAN REVISED TO SHOW THAT ALL PIPING EXCEPT YARD PIPING IS NEW.
ALSO, PLAN SHOWS 2 UNITS ON ROOF.
BOND NEW PIPING