Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/05/2006 | FRAMING | Approved | IVRS - Inspection :* | |
| 01/31/2006 | FRAMING | Partial Approval | IVRS - Inspection :* 1) ALL ELECTRIC WIRES SHALL BE STAPLED WITHIN 8" OF BOX 2) SMOKE ALARM MISSING OUTSIDE OF MASTER BEDROOM AND MUST BE INTERLOCKED WITH BEDROOM S.A. 3) PROTECT ALL ABS PLUMBING CLOSER THAN 1 1/4" TO FACE OF STUDS 4) #12 WIRE REQUIRED AT VANITY OUTLET GFI WITH NO OTHER OUTLETS OR SWITCHES ON THIS LINE 5) TIE ALL GROUND WIRES WITH ELECTRIC CONNECTORS |
|
| 01/12/2006 | FRAMING | Partial Approval | IVRS - Inspection :* 1) MAKE UP ALL ELECTRIC WIRES IN J-BOXES 2) COMPLETE ALL PLUMBING TOP-OUT 3) COMPLETE MECHANICAL INSTALLATION 4) COMPLETE ALL ELECTRIC ROUGH IN |
|
| 01/06/2006 | FRAMING | Not ready for Inspection | COMPLETE ALL TRADES PRIOR TO FRAME INSPECTION |