Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: BUILDING - FINAL
Permit Number - T05CM05686
Inspection Description - BUILDING - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
06/30/2010 | BUILDING - FINAL | Approved | IVRS - Inspection :* | |
06/16/2010 | BUILDING - FINAL | Partial Approval | IVRS - Inspection :* SEE NOTE 3 FROM PREVIOUS INSPECTIONS |
|
06/08/2010 | BUILDING - FINAL | Partial Approval | IVRS - Inspection :* 1) RELOCATE SMOKE ALARMS 6"-12" FROM CEILING 2) PROVIDE STUCCO CERT 3) LABEL CIRCUITS IN SUB-PANEL |
|
05/26/2010 | BUILDING - FINAL | Partial Approval | IVRS - Inspection :* 1) CHECK FASTENERS LATHE 6" ON CENTER TOP AND BOTTOM PLATRS. REINFORCE ALL WINDOWS 2) NOTE 4 FROM PREVIOUS 3) PROVIDE 4" CLEARANCE WEEP SCREED FROM SOIL. GRADE AWAY FROM BLDG |
|
03/04/2010 | BUILDING - FINAL | Not ready for Inspection | IVRS - Inspection :* | |
12/05/2005 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* |