Permit: T05CM05677

Parcel: 133426050

Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Date Description Inspector Results Comments
12/05/2005 PLUMBING - INTERMEDIATE Approved SOIL WATER TEST IS OK
WATER DISTRIBUTION IS OK
OK FOR DRY WALL
11/30/2005 PLUMBING - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*SHALL PROVIDE A C.O @ VERTICAL RISER FOR KITCHEN SINK
CANNOT REDUCE THE TRAP ARM FROM 2" TO 1 1/2 FOR KITCHEN SINK. IF YOU USE A 2" TRAP ARM THEN A 2" A 1/2" TRAP ARM FROM THE BARREL TO THE P-TRAP.
SHALL LOCATE HORIZONTAL VENT 6" ABOVE FLOOD RIM LEVEL OR PROVIDE 45 DEGREE.
SHALL PROVIDE A WATER TEST ON NEW PIPEING TO TOP OF VENT.
OK TO DRY WALL ALL OTHER AREAS