Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/28/2006 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection :* | |
| 04/27/2006 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* WASTE & VENT WATER TEST STOOLS & URINGAL OK CORRECTION TO WATER SUPPLY TO WOMEN'S STOOL OK WOMEN RESTROOM OK CAPS ON UNDERGROUND DEMO OK NEED TO SEE INSPECTION ON VENT IN WALL MENS RESTROOM WHEN PUT BACK TOGETHER & URINAL SUPPORT OVERHEAD VENTS REQUIRE CORRECT PERM CAPS. NEED TO SEE CLOSET FLANGES PRIOR TO STOOLS. |
|
| 04/25/2006 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* YOU DID NOT LEAVE A PHONE# ON YOUR MESSAGE. 1. PROVIDE TEST ON WASTE & VENT PIPING. 2. NOTE: HANDICAP STOOL IN WOMENS RESTROOM SHALL HAVE FLUSH HANDLE TO WIDE SIDE OF STALL. 3. INSTALL FLOOR MOUNT URINAL CARRIER PER PLAN. |