Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/05/2006 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 01/04/2006 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) RSP4'S MISSING ON EAST AND WEST GABLE'S AT TOP PLATE TO TRUSS 2) STRAP MISSING ON NORTH WALL COVER 3) SHEAR TRANSFERS NOT NAILED OFF AT ROOF |