Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T05CM05630

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
01/25/2006 FRAMING Approved IVRS - Inspection :*
01/24/2006 FRAMING Cancelled CANCELLED PER SUPERINTENDENT TRAVIS #240-8413
01/23/2006 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) ANCHOR BOLTS LOOSE THROUGHOUT
2) TOP 1/3 OFF WAY NOT STAPLED
3) PENETRATIONS NOT SEALED
4) ELECTRIC NOT COMPLETE AT KITCHEN
5) CANNOT RUN ELECTRIC AND H20 TO SAME HOLE IN KITCHEN
6) PROVIDE NAIL PLAT CONDENSATE
7) MOVE SMOKE DETECTOR AT HALL WAY ? MUST BE 6" FROM CEILING TO TOP
8) BRACE 4 GANG BOX AT LIVING ROOM