Inspection History Details
Inspection Status: Approved
Inspection History: BUILDING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/20/2007 | BUILDING - FINAL | Approved | IVRS - Inspection :* | |
| 03/19/2007 | BUILDING - FINAL | Partial Approval | IVRS - Inspection :* 1) COMPLETE ITEMS 7, 9 & 11 AND RECALL |
|
| 03/12/2007 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) BEDROOM CIRCUITS TO BE ARC FAULT PROTECTED 2) INSTALL DRIP LEGS ALL GAS APPLIANCES 3) CONNECT DRYER ELECTRIC AND DUCT VENT 4) INSTALL DISHWASHER 5) INSTALL WATER AND GAS BONDS TO MAIN ELECTRIC PANEL 6) INSTALL ANTI-TIP ON KITCHEN STOVE 7) MIN 36" X 36" LANDING REQUIRED OUTSIDE EXIT DOORS 8) PAINT EXPOSED PVC CONDENSATE EXTERIOR 9) MAX FUSE A/C 25 AMP 10) COMPLETE GRADING SLOPE AWAY FROM HOUSE 11) IF NOT USING GAS FOR DRYER INSTALL GAS COCK SHUT OFF AND CAP OFF |