Permit: T05CM05607

Parcel: 115154840

Inspection Status: Approved

Inspection History: BUILDING - FINAL

Date Description Inspector Results Comments
03/20/2007 BUILDING - FINAL Approved IVRS - Inspection :*
03/19/2007 BUILDING - FINAL Partial Approval IVRS - Inspection :*
1) COMPLETE ITEMS 7, 9 & 11 AND RECALL
03/12/2007 BUILDING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) BEDROOM CIRCUITS TO BE ARC FAULT PROTECTED
2) INSTALL DRIP LEGS ALL GAS APPLIANCES
3) CONNECT DRYER ELECTRIC AND DUCT VENT
4) INSTALL DISHWASHER
5) INSTALL WATER AND GAS BONDS TO MAIN ELECTRIC PANEL
6) INSTALL ANTI-TIP ON KITCHEN STOVE
7) MIN 36" X 36" LANDING REQUIRED OUTSIDE EXIT DOORS
8) PAINT EXPOSED PVC CONDENSATE EXTERIOR
9) MAX FUSE A/C 25 AMP
10) COMPLETE GRADING SLOPE AWAY FROM HOUSE
11) IF NOT USING GAS FOR DRYER INSTALL GAS COCK SHUT OFF AND CAP OFF