| 03/02/2006 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 02/21/2006 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) STRAP NON OVER LAPPING DBL TOP PLATE N.W. CORNER ENTRY 2) STRAP OVER FRAME ROOF TO STRUCTURE 3) CS 20 STRAPS MISSING GARAGE SHEAR AND ENTRY WALL AT EVERY OTHER STUD 1/SD2 4) PROVIDE SHEAR BLOCKING PANELS BY ENTRY PER 6/SD2 5) SOUTH WALL MISSING CS STRAPS-MUST USE 8D'S IN OSB NOT TECO |
|
| 02/01/2006 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) ROOF SHEATHING NOT ON 2) EXTERIOR CLIP NOT READY 3) NEXT FAILURE WILL CHARGE A REFEE |