Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/15/2006 | FRAMING | Approved | IVRS - Inspection :* | |
| 03/14/2006 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) HOLDOWN NUTS LOOSE 2) OK TO INSULATE |
|
| 03/10/2006 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) UFER CUT REPAIR OR INSTALL GROUND RODS 2) INSTALL DRYER HOOD AND SEAL STUCCO PENETRATIONS 3) HOLDOWN NUTS MISSING 4) NO GAS TEST 5) ANCHOR INTERIOR BEARING WALL 6) OK TO INSULATE |
|
| 03/08/2006 | FRAMING | Denied | IVRS - Inspection : Work is not complete enough to inspect.| 950* 1) NO GAS TEST 2) SHORT RADIUS 90 CANNOT BE AT BOTTOM OF DWV STACK 3) HORIZONTAL DWV DRAIN MUST HAVE 1/4" PER FT PITCH 4) HOLDOWN NUTS LOOSE 5) SEAL LATHE PENETRATIONS 6) RED HEAD ANCHOR BOLTS LOOSE 7) STOPPED INSPECTION-TOO MANY ITEMS |
|
| 03/06/2006 | FRAMING | Cancelled | CANCELLED PER TIM OF K.B. HOMES #907-6040 |