Permit: T05CM05589

Parcel: 140373770


Addresses:

7091 S PLOVER CT

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
05/15/2006 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
04/21/2006 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NORTH WALL TWO STUDS OVER SPAN
2) P-3 SHEAR NOT NAILED AT 3" & 12"
3) SECOND FLOOR BOTTOM PLATE NOT FULL BEARING ON SECOND FLOOR
4) P-1 NOT NAILED ABOVE ENTRY
5) RIBBON NOT NAILED ABOVE ENTRY
6) GIRDER TRUSS DBL 2 X POSTS TO SHORT-NOT BEARING
7) ROOE LOOSE-RENAIL ALL SHINERS