Permit: T05CM05587

Parcel: 140377650

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
03/31/2006 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
03/28/2006 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
A reinspection fee has been assessed for this inspection. Multiple inspection
CS-20 straps not installed at every other stud on rear p-1 shearwall per 1/sd2-repeat
Continous dbl 2 x posts required under girder truss missing two locations in garage-repeat
03/27/2006 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) TWO EACH DBL 2 X 4 POSTS MISSING IN GARAGE AT RIBBON
2) CS 20 STRAPS MISSING AT REAR OF HOUSE ON SHEARWALL
3) NO LADDER ACCESS TO ROOF
03/21/2006 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) DBL 2 X 4 POSTS MISSING UNDER GIRDER TRUSS TO GROUND
2) CS 20 STRAPS NOT PROPERLY INSTALLED OR NAILED-MANY MISSING
3) NO LADDER ACCESS TO SECOND FLOOR ROOF