Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/03/2006 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 03/31/2006 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) 3 EACH CS 20 STRAPS MISSING ABOVE ENTRY |
|
| 03/30/2006 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : A reinspection fee has been assessed for this inspection. Multiple inspection No change Refee |
|
| 03/27/2006 | EXT METAL CLIPS/EXT SHEATHING | Cancelled | CALL FOR CANCELLATION CAME IN AT 8:24AM FROM WILL OF K.B. HOMES #275-8689. CALLED INSPECTOR J. RIVA TO LET HIM KNOW THAT THIS INSPECTION WAS CALLED IN AS A CANCELLATION, HE ASKED WHAT TIME IT WAS CALLED IN I TOLD HIM AND HE SAID HE HAD ALREADY BEEN BY TO DO INSPECTION PRIOR TO CALL RECEIVED FOR CANCELLATION | |
| 03/27/2006 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : Work is not complete enough to inspect.| 950* 1) P-3 SHEARWALL NOT NAILED PER PLAN 2) TRUSS BLOCKING PANELS MISSING S.W. CORNER OF GARAGE 4 BAYS 3) CLIP ALL 3 STUDS OF BUILT UP POSTS 4) P-1 SHEAR PANEL NOT NAILED AT REAR 5) SECOND FLOOR REAR P-1 SHEARWALL LOOSE 6) OSB ROOF PANELS MUST BE INSTALLED WITH LONG DIMENSION/GRAIN ACROSS TRUSSES 7) ROOF COVERED WITHOUT INSPECTION-REMOVE 8) STOPPED INSPECTION |