Permit: T05CM05572

Parcel: 140377730

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
03/21/2006 FRAMING Approved IVRS - Inspection :*
03/20/2006 FRAMING Cancelled CANCELLED PER TIM OF K.B. HOMES #907-6040
03/20/2006 FRAMING Not ready for Inspection IVRS - Inspection :*
03/17/2006 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) BEARING WALL STUD OUT BY RANG HOOD
2) NO SECOND FLOOR DWV WATER TEST
3) FIRE BLOCK REQUIRES 2 LAYERS OF 1/2" OSB
4) FIRE STOP WATER HEATER VENT AT CEILING 2ND FLOOR
5) FURNACE B-VENT NOT PROPERLY INSTALLED-SEE MANUAL
6) RANGE DUCT BELOW CEILING-PROVIDE CHASE
03/10/2006 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) LATH NOT COMPLETE
2) RED HEADS LOOSE AND MISSING
3) NO GAS BOND
4) DEAD HEAD PLUMBING EITHER REMOVE OR PROVIDE CITY APPROVED PLAN AND PIMA COUNTRY SEWER FEES
5) PLUMBING OUT OF WALL
6) NAIL PROTECT PLUMBING AND ELECTRIC
7) FIRE BLOCK SECOND FLOOR
8) 6" REQUIRED PEX TO B-VENT
9) NO GAST TEST
10) OVER BORED BEARING STUDS AT KITCHEN DBL STUDS OR STUD SHOES
11) ? PROTECT PEX
12) SUPPOR DWV AND GAS LINE
13) FIRE BLOCK MASTER BEDROOM
14) FIRE STOP WATER HEATER CHASE