Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/07/2006 | FRAMING | Approved | IVRS - Inspection :* 1) VERIFIED ENGINEERING FOR 2' X 3' HOLE CUT IN SLAB |
|
| 05/12/2006 | FRAMING | Partial Approval | IVRS - Inspection :* 1) OK TO COVER ALL BUT SLAB REPAIR 2) PROVIDE ENGINEERING FOR 2' X 3' HOLE IN SLAB WITH CUT CABLES |
|
| 05/10/2006 | FRAMING | Partial Approval | IVRS - Inspection :* 1) PROVIDE ENGINEERING FOR CABLES CUT IN POST TENSION 2) MISSING ANCHOR BOLT AT BOTTOM PLATE IN SOUTH WALL AT SEPERATION 3) OVER KNOTCHING ON B-VENT WATER HEATER DBL TOP PLATE 4) OK TO INSULATE ALL EXCEPT W/H CLOSET AND SOUTH WALL OF GARAGE |
|
| 05/08/2006 | FRAMING | Cancelled | IVRS - RI canceled | |
| 05/04/2006 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
|
| 04/28/2006 | FRAMING | Denied | IVRS - Inspection : Work is not complete enough to inspect.| 950* 1) HORIZONTAL "B" VENT CANNOT BE MORE THAN 60 DEGREE FROM VERTICAL 2) PEX MUST BE 6" FROM "B" VENT 3) NO DWV WATER TEST 4) NAIL PROTECT WIRES 5) NO GAS TEST 6) STOPPED INSPECTION 7) HOUSE NOT READY |
|
| 04/24/2006 | FRAMING | Not ready for Inspection | IVRS - Inspection :* 1) NO PLANS/PERMITS 2) NO DWV TEST 3) NO SUPPLY TEST 4) NAIL STRAP W. WALL LAUNDRY 5) STOPPED INSPECTION |