Permit: T05CM05565

Parcel: 124161510


Addresses:

1013 S TYNDALL AV

Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Date Description Inspector Results Comments
07/24/2006 PLUMBING - INTERMEDIATE Approved IVRS - Inspection :*
05/18/2006 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
INSTALLED PER REDLINED CHANGES ON PLAN
FINAL APPROVAL UPON PLAN REVISION.
05/16/2006 PLUMBING - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*
PREVIOUS CORRECTIONS NOT MADE.
MET W/ERNESTO (PLUMBER).
YOUR PLAN CLEARLY SPECIFIES THAT:
1. TYPE L COPPER TUBE IS TO BE USED FOR DOMESTIC WATER PIPING.
2. WATER SERVICE ENTERS BUILDING ON WEST END NOT ON SOUTHSIDE.
3. BUILDING DRAIN IS 4".
PIPING INSTALLATIONS ARE NOT PER PLAN.
YOU WERE MADE AWARE OF THIS ON FEBRUARY 2ND
IF YOU WISH TO INSTALL PIPING IN A MANNER OTHER THAN SPECIFIED ON PLAN. YOU NEED TO REVISE PLAN ACCORDINGLY. PLAN SPECS SUPERCEDE UPC MIN. STANDARDS
05/12/2006 PLUMBING - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*
CLEAN OUT EXTENSIONS SHALL BE WYE BRANCH FITTINGS.
VTR SHALL BE 3"
CLEAN OUT ABOVE LAV WILL INTERFERE WITH MIRROR.
HORIZONTAL CHANGES OF DIRECTION ON TRAP ARM SHALL BE MADE WITH THE USE OF WYE PATTERN FITTINGS.
CLOSET FLANGE SHALL BE FASTENED TO FLOOR.
WH REQUIRES A DRAIN PAN AND DRAIN.
PLAN CALLS FOR WATER PIPING TO BE TYPE L COPPER.
PEX HAS BEEN INSTALLED
PEX NOT INSTALLED PER CODE.
03/15/2006 PLUMBING - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*
THE CORRECTIONS FROM YESTERDAYS INSPECTION HAVE NOT BEEN MADE
3" SEWER INCREASES TO 4" AT APPROX. 10 FT FROM BUILDING
1. A FULL SIZED CLEANOUT IS REQUIRED AT THIS LOCATION
2. PROVIDE A TEST ON SEWER PIPING.
DO NOT USE WATER FROM AN UNPROTECTED SUPPLY!
IMMEDIATELY INSTALL A HOSE BIBB VAC BREAKER ON TEMPORARY HOSE BIBB
03/14/2006 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
CARDS HCS, WATER LINE
631-4045
03040 - YARD WATER LINE AND 03055 PLUMBING SEWER ARE NOT ON INSPECTION CARD BECAUSE THE PLAN INDICATES THAT THESE ARE EXISTING.
WATER PIPING PLAN DOES NOT SHOW BACKFLOW SERVICE PROTECTION.
OK TO COVER 1" PVC YARD WATER LINE. I WILL NEED TO SEE THE RP INSTALLATION AT A LATER TIME.
REVISE PRINT TO SHOW BACKFLOW PREVENTION ASSEMBLY AND LOCATION OF WATER LINE. INSTALL A
HOSE BIB VACUUM BREAKER ON TEMPORARY CONSTRUCTION HB
BUILDING SEWER REQUIRES A TEST. DO NOT COVER. PROVIDE A 4" CLEANOUT FOR SEWER.