Permit: T05CM05564

Parcel: 140550990

Inspection Status: Approved

Inspection History: BUILDING - FINAL

Date Description Inspector Results Comments
04/05/2007 BUILDING - FINAL Approved IVRS - Inspection :*
03/15/2007 BUILDING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) PER IRC 312.1 STAIRS HIGHER THAN 30" ABOVE FLOOR REQUIRE MINIMUM 34" HIGH GUARD RAILS ABOVE STAIR NOSING
2) STAIR HANDRAIL MUST BE 36" PLUS/MINUS 2" ABOVE STAIR NOSE-PRESENTLY 28"
03/14/2007 BUILDING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) HOUSE LOCKED-NO ACCESS
2) OUTDOOR LIGHTING DOES NOT COMPLY WITH OUTDOOR LIGHTING CODE
12/11/2006 BUILDING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) GFI COVER AT ENTRY LOOSE
2) GFI BOX COVER MISSING PATIO
3) ANTI-SIPHON MISSING HOSE BIB REAR OF HOUSE
4) CLEANOUT COVER MISSING BACK OF HOUSE
5) A/C UNIT NOT READY FOR INSPECTION
6) RANGE HOOD NOT WORKING