Inspection History Details
Inspection Status: Approved
Inspection History: BUILDING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/24/2006 | BUILDING - FINAL | Approved | ||
| 08/23/2006 | BUILDING - FINAL | Partial Approval | IVRS - Inspection :* | |
| 08/21/2006 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. H.C PARKING SIGNS TO BE MOUNTED 84" TO BOTTOM OF SIGN PER TDOT 2. INSULATION KIT REQUIRED ON ACCESSIBLE LAVATORIES 3. SHOWER IN BRIDES ROOM MUST MEET ACCESSIBILITY STANDARDS FOR THRESHOLD CONTROLS AND SHOWER HEAD MOUNTING -- PER YOUR PLAN. 4. RESTROOMS REQUIRE SIGNAGE PER CH. 11 IBC MOUNT SIGNS ON WALL; LATCH SIDE OF DOORS. |
|
| 08/14/2006 | BUILDING - FINAL | Partial Approval | IVRS - Inspection :* BRIDAL ROOM SHOWER NOT ACCESSIBLE -- NEED FIRE FINAL 240-1087 JOE |
|
| 06/30/2006 | BUILDING - FINAL | Not ready for Inspection | IVRS - Inspection :* ANY PUBLIC SHOWER MUST BE MADE ACCESSIBLE. |
|
| 06/29/2006 | BUILDING - FINAL | Not ready for Inspection | IVRS - Inspection :* FINISH ALL WORK 1. INSPECTION CALLED FOR CONSIDERATION OF TEMPORARY OCCUPANCY - I CANNOT RECOMMEND TCO FOR THIS PROJECT BECAUSE: A. SCOPE AND SIZE OF THIS PROJECT IS NOT WITHIN NORMAL C.O.T PARAMETERS TO ALLOW TCO B. ELECTRICAL WIRING INCOMPLETE - INCLUDING IMPROPER MAKEUP OF EMERGENCY LIGHTING OUTLETS. C. PLUMBING INSPECTIONS WERE NEVER CALLED FOR INTERMEDIATES AND GAS PIPE INSPECTION HAS FAILED. D. KITCHEN MECHANICAL SYSTEMS ARE INCOMPLETE. E. REQUIRED FLASHING AT BAR AREA (SINKS & COUNTERS TO WALL) HAS NOT BEEN INSTALLED. 2. IF YOU WISH TO APPEAL MY DECISION PLEASE SEE STEVE LONG @ 201 N. STONE AV. |
|
| 06/27/2006 | BUILDING - FINAL | Not ready for Inspection | IVRS - Inspection :* LIGHT CAISSONS IN PARKING LOT |