Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/12/2006 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 02/02/2006 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) STRAP NON OVER LAPPING DBL TOP PLATES 2) CS 20 STRAPS MUST BE TIGHT 3) NAIL PROTECT PLUMBING 4) PROVIDE PHYSICAL PROTECTION FOR SEWER 5) PORCH HIP TRUSS NOT CLIPPED |
|
| 01/31/2006 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) 7 SD3 NOT COMPLIED WITH 2) GARAGE HEADER TRUSS NOT CLIPPED 3) GARAGE HEADER REQUIRES 3 KING STUDS 4) HIP TRUSS NOT CLIPPED 5) STOPPED INSPECTION-TO MANY ITEMS |
|
| 01/27/2006 | EXT METAL CLIPS/EXT SHEATHING | Cancelled | CANCELLED PER TIM OF K.B. HOMES #907-6040 |