Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/06/2006 | FRAMING | Approved | IVRS - Inspection :* | |
| 04/03/2006 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) OK TO INSULATE 2) INADEQUATE HEAD ROOM AT STAIRS-REQUIRES 6'-8" FINISHED |
|
| 03/30/2006 | FRAMING | Denied | IVRS - Inspection : A reinspection fee has been assessed for this inspection. Multiple inspection Red heads anchor bolts loose-repeat Support horizontal dwv at 4' on center-repeat Seal floor penetrations Stopped inspection Refee This house has not had a complete inspection |
|
| 03/28/2006 | FRAMING | Denied | IVRS - Inspection : Work is not complete enough to inspect.| 950* |
|
| 03/27/2006 | FRAMING | Denied | IVRS - Inspection : Work is not complete enough to inspect.| 950* 1) RED HEAD ANCHOR BOLTS LOOSE 2) SEAL FLOOR PENETRATIONS 3) NO GAS PRESSURE TEST 4) SUPPORT HORIZONTAL DWV AT 4' ON CENTER 5) STAIRS DO NOT HAVE 6'-8" FINISHED HEAD ROOM 6) PROVIDE 22" X 48" OVER FRAM ATTIC ACCESS 7) FIRE STOP ALL CHASES 8) NO SECOND FLOOR DWV WATER TEST 9) BLOCK DUCT BOOTS 3 SIDE 10) STOPPED INSPECTION-TOO MANY ITEMS |