Permit: T05CM05553

Parcel: 140377670

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
04/06/2006 FRAMING Approved IVRS - Inspection :*
04/03/2006 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) OK TO INSULATE
2) INADEQUATE HEAD ROOM AT STAIRS-REQUIRES 6'-8" FINISHED
03/30/2006 FRAMING Denied IVRS - Inspection :
A reinspection fee has been assessed for this inspection. Multiple inspection
Red heads anchor bolts loose-repeat
Support horizontal dwv at 4' on center-repeat
Seal floor penetrations
Stopped inspection
Refee
This house has not had a complete inspection
03/28/2006 FRAMING Denied IVRS - Inspection :
Work is not complete enough to inspect.| 950*
03/27/2006 FRAMING Denied IVRS - Inspection :
Work is not complete enough to inspect.| 950*
1) RED HEAD ANCHOR BOLTS LOOSE
2) SEAL FLOOR PENETRATIONS
3) NO GAS PRESSURE TEST
4) SUPPORT HORIZONTAL DWV AT 4' ON CENTER
5) STAIRS DO NOT HAVE 6'-8" FINISHED HEAD ROOM
6) PROVIDE 22" X 48" OVER FRAM ATTIC ACCESS
7) FIRE STOP ALL CHASES
8) NO SECOND FLOOR DWV WATER TEST
9) BLOCK DUCT BOOTS 3 SIDE
10) STOPPED INSPECTION-TOO MANY ITEMS