Permit: T05CM05502

Parcel: 141092770


Addresses:

6626 E SPLENDID LN


Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T05CM05502

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
05/10/2006 FRAMING Approved IVRS - Inspection :*
05/08/2006 FRAMING Denied IVRS - Inspection :
There is no plan or job inspection card on site.| 925*
1) NO PLANS/PERMIT ON SITE
05/02/2006 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) ITEMS FROM 4/13/06 NOT DONE
2) ANCHOR BOLTS LOOSE
3) REVERSE PITCH LAV DIRTY ARM
4) SHEARWALL #5 HOLDOWN IN WRONG LOCATION SEE PLAN
5) 17/D-1 NOT NAILED AT 12" ON CENTER
04/13/2006 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) FROM LAST INSPECTION TRUSSES FRONT BEDROOM 3 PST BEARING TWO TRUSSES ARE IN WRONG LAYOUT, ROOF IS LOADED
2) LEAVE TRUSS DRAWINGS OR INSTALL LATERAL BRACES AT GARAGE ABOVE DEAD WOOD
3) BLOCK OUT AT DUCTS IN GARAGE LID
4) LOCATE ATTIC ACCESS
5) NOTE EXT. CABLE WIRES IN REAR POP-OUT