Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T05CM05492

Parcel: 125030850


Addresses:

2914 E 4TH ST

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
03/15/2006 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
03/13/2006 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) COMPLETE NAILING 6" ON CENTER ALL PANEL EDGES AND ENDS 12" ALL FIELD NAILIN
2) NAIL ALL CLIPS
02/10/2006 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NAILS ONLY IN HARDWARE NO DRYWALL SCREWS
2) INSTALL BRACED WALL PANELS
3) COMPLETE ALL EXTERIOR HEADERS
4) NAIL FACIA
5) STOPPED INSPECTION