Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/28/2006 | FRAMING | Approved | IVRS - Inspection :* 1) ITEM 03050 NOT REQUIRED PER PAPERWORK TURNED IN BY INSPECTOR |
|
| 02/27/2006 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) TIGHTEN ABS 2) NO DWV 3) FIRESTOP 2ND FLOOR PEN 4) SUPPORT DRAIN OVER GARAGE 5) NAIL PROTECT PEX AT STAIRS 6) WIRE EXHAUST FAN 7) SEAL VAPOR BARRIER 8) SUPPORT WASHER PAN DRAIN 9) PEX ON TRUSS GUSSET OVER ENTRY 10) TERMINATE AIR HANDLER CONDUCTOR IN BOX 11) SUPPORT VTR 90 12) STOPPED INSPECTION-TOO MANY ITEMS |
|
| 02/26/2006 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) COMPLETE LATH 2) TIGHTEN AB'S 3) FIRESTOP 2ND FLOOR PENETRATIONS 4) FIRE BLOCK GARAGE/ENTRY 5) TO MANY WIRES PER STAPLE FOLLOW MANUFACTURERS RECOMENDATIONS 6) FIRE STOP CHASE AT STAIRS 7) STOPPED INSPECTION |