Permit: T05CM05466

Parcel: 118272730

Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T05CM05466

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
02/28/2006 FRAMING Approved IVRS - Inspection :*
1) ITEM 03050 NOT REQUIRED PER PAPERWORK TURNED IN BY INSPECTOR
02/27/2006 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) TIGHTEN ABS
2) NO DWV
3) FIRESTOP 2ND FLOOR PEN
4) SUPPORT DRAIN OVER GARAGE
5) NAIL PROTECT PEX AT STAIRS
6) WIRE EXHAUST FAN
7) SEAL VAPOR BARRIER
8) SUPPORT WASHER PAN DRAIN
9) PEX ON TRUSS GUSSET OVER ENTRY
10) TERMINATE AIR HANDLER CONDUCTOR IN BOX
11) SUPPORT VTR 90
12) STOPPED INSPECTION-TOO MANY ITEMS
02/26/2006 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) COMPLETE LATH
2) TIGHTEN AB'S
3) FIRESTOP 2ND FLOOR PENETRATIONS
4) FIRE BLOCK GARAGE/ENTRY
5) TO MANY WIRES PER STAPLE FOLLOW MANUFACTURERS RECOMENDATIONS
6) FIRE STOP CHASE AT STAIRS
7) STOPPED INSPECTION