Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/27/2006 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 02/26/2006 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) TRADES NOT COMPLETE |
|
| 02/24/2006 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) 3 POINT BEARING TRUSSES OVER INTERIOR GARAGE WALL NOT REPAIRED YET 2) REMOVE ALL DRYWALL LOADING CENTER OF 2ND FLOOR 3) DO NOT LOAD ROOF 4) INTERMEDIATES WILL NOT OCCUR PRIOR TO EXT. CLIP APPROVAL |
|
| 02/17/2006 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) TIE DOWN GABLE ENDS 2) X-BRACE GABLES PER PLAN 3) 3 POINT BEARING FLOOR TRUSSES NOT BEARING OVER WALL-PROVIDE ENGINEERING 4) EXTERIOR OF HOUSE IS OK-APPROVED TO LATH 5) DO NOT LOAD ROOF 6) SHEAR PANELS REQUIRED OVER INTERIOR GARAGE SHEAR |
|
| 02/09/2006 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) CLIPS MISSING NAILS 2) REPLACE DAMAGED STUDS 3) STRAP NOT NAILED NORTH WALL 4) PATIO NOT FRAMED |
|
| 01/25/2006 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) FINISH SHEAR NAILING NORTH SIDE AND BLOCK ALL EDGES 2) PATIO FOOTERS NOT PER PLAN AND PATIOS NOT FRAMED 3) SHEAR NOT NAILED TO STUD AT GARAGE 4) GABLE BRACING NOT PER PLAN 5) CHECK SHEAR SHINERS THROUGHOUT 6) BIRD BOARDS BEING USED FOR RIDGE BLOCKING 7) PROVIDE TRUSS CALCS 8) STOPPED INSPECTION |